11.0 TEST STATION READINES - AutoAdjust Program
11.1 The autoadjust program can be executed while logged in the user1 account. This program will also run automatically whenever there is greater than a 5 degree change in the testhead air temperature.
11.2 To manually run the autoadjust program, type autoadjust at the BT-BASIC command
line and press the “ENTER” key on the keyboard.
11.3 The program will begin executing and you will see the BT-BASIC window go blank.
11.4 The following message will appear in the BT-BASIC window:
AutoAdjust: xxx of 472 tests completed.
11.5 The number in value xxx will increment from 1 to 472 as the test runs. When the testing
is completed the system will restore the default BT-BASIC window, reference figure 7.
11.6 The test status will be displayed on the status line of the BT-BASIC window:
Completed = passed or AutoAdjust Failed = failed
11.7 If the autoadjust program fails, first manually re-run the “autoadjust” program. If
autoadjust continues to fail then the test system self test should be run.
Note: If autoadjust fails, the test system should not be used for production testing until the problem has been corrected. Notify the test engineering department.